Maintenance on the clamping unit requires re-adjustment of the holding load. It is therefore recommended to send the clamping unit to Hänchen for maintenance.
Components of a clamping unit with single-piece cover and one spring
|
|
Warning | Danger of life due to spring-loaded parts!
|
To replace the seal yourself, first remove the clamping unit from the machine and then disassemble the clamping unit Ratio-Clamp®.
Removal from the machine
Disassemble clamping unit
To replace the seal yourself, disassemble the cover of the clamping unit Ratio-Clamp® on the functional rod of your machine.
Removal from the machine
Disassemble clamping unit
To install the clamping unit in the key design ready for mounting - secured with the key - a functional rod is required.
We recommend installing the key design of the clamping unit according to the clamping unit without key directly on the functional rod.
For clamping unit in key design